Dell’s C6220 II server squeezes four Xeon E5-2600 v2 systems into 2U of rack space, essentially doubling density. It is sometimes called "Killer of 1U form factor" server ;-)
C6220 was released in April 26, 2012 and in 2013 updated for Xeon E5-2600 v2 line of Intel CPUs. It is a custom machines for very large customers who want fewer bells and whistles but higher computing density and lower power consumption. The PowerEdge C6220 is being marketed as a high-density server solution primarily targeting HPC (high-performance computing) and virtual server clusters.
It has weak onboard RAID controller (mainly for Windows, for Linux you need at least $200 additional card and only 1Gbit NIC cards on the motherboard. So it you want 10Gbit you need to put an additional card.
The C6220 offers four completely independent, hot-swappable server nodes. Each server node can be configured independently of the other nodes in the same chassis to perform specific tasks. They can have different CPUs, different amount of memory and different number of hard drive, providing better flexibility in respect to harddrives that 1U servers. The chassis also accepts a pair of dual-height nodes which have two PCI-e expansion slots.
The four nodes are accessed at the rear where each one provides dual Gigabit ports (not 10GBit), IPMI, two USB2 port, VGA and a serial port.
C6220 allow to use CPUs consuming up to 135W. This means the entire range of E5-2600 and v2 CPUs is supported.Expand your I/O bandwidth and enhance the capabilities of any PowerEdge C6220 II configuration with PCIe 3.0-capable slots.
C6220 II can be used in various high-workload-intensive environments.
Remote management is done differently then in standard Dell servers -- not via DRAC but via so called Baseboard Management Controller (BMC), which is a microcontroller located on the server’s system board. BMC provides the “intelligence” within the IPMI architecture, responsible for monitoring and controlling the server’s manageable devices. Capabilities are very similar to DRAC but organized in diferent menus. It also has Java console. Among features:
Out-of-band monitoring and control for server management over LAN
Dedicated NIC for remote management via network
FRU information report, which includes system board part number, product name, and manufacturer.
Health status/hardware monitoring report
View and clear events log
Event notification by lighting chassis LED indicator and Platform Event Trap (PET)
Platform Event Filtering (PEF) to take selected action for selected events
Chassis management, which includes power control, status report, front
panel buttons, and LEDs control
sled management.
Drives are installed in enclusure not in sled. Up to 12 x 3.5" or 24 x 2.5" hot-swappable SAS, SATA or SSD drives are supported. Thar means 48TB SATA and 48TB SAS maximum storage per chassis.
You can allocate different number of harddrives to each node if you use 2.5" expander backplane:
Get up to 40% greater performance and improved energy efficiency in the same award-winning PowerEdge™ C6220 shared infrastructure chassis with the latest Intel® Xeon® E5-2600v2 processors.
Feature | PowerEdge C6220 II technical specifications | |||
Chassis | 2U rack mount | |||
Processors | Up to four 2-socket
servers, 4, 6, 8, 10 or 12 cores per processor
Intel Xeon processor E5-2600v2 product family, with L3 cache: up to 30MB |
|||
Memory | 16 DIMM slots for up to 512GB per
node:
|
|
||
Chipset | Intel C602 chipset | |||
Video | Integrated AST2300 with up to 16MB video RAM | |||
Primary storage | Maximum internal storage: 48TB SATA or NL 48TB SAS | |||
Drive bays and hard drives | 24 x 2.5" or 12 x 3.5"
hard drive options
2.5" SAS (15K): 146GB, 300GB 2.5" SAS (10K): 600GB, 900GB, 1.2TB 2.5" SATA: 500GB, 1TB 2.5" NL SAS (7.2K): 1TB 2.5" SATA SSD (eMLC): 100GB, 200GB, 400GB, 800GB |
3.5" SATA (7.2K): 1TB, 2TB, 3TB,
4TB
3.5" SAS (15K): 600GB 3.5" NL SAS (7.2K): 2TB, 3TB, 4TB |
||
Connectivity | Intel Ethernet Controller i350, 2 x 1Gb Ethernet; 1 x 100Mb Ethernet dedicated management port | |||
USB ports | 2 external ports | |||
I/O slots | 1U-node version: 1
x8 mezzanine, 1 x16 half-height (low profile), half-length slot
2U-node version: 1 x8 mezzanine slot; 1 x16 full-height, half-length slot; 1 x16 full-height, full-length slot |
|||
I/O adapter options | 1Gb Ethernet
Intel i350 quad-port 1Gb adapter Intel 82580 ET quad-port 1Gb mezz 10Gb Ethernet Intel 82599 dual-port 10Gb DA/SFP + mezz Intel X520 dual-port 10Gb DA/SFP + mezz |
InfiniBand
Mellanox® ConnectX®-2 QDR dual-port mezz Mellanox ConnectX-3 FDR single-port mezz Dell X410 host interface card (HIC) for connection to the C410x |
||
Drive and RAID controllers | Intel C602: SATA or
SSD drives only
LSI® 2008 6Gbs SAS mezzanine (optional) LSI 9265-8i 6Gbs SAS add-in controller (optional) |
|||
Power supplies | Dual hot-plug redundant high-efficiency 1200W or 1400W power supplies | |||
Fans | Shared cooling with quick-disconnect 4x 60mm speed fans detectable with PWM control | |||
Operating systems | Novell® SUSE® Linux
Enterprise Server 11 SP2
Red Hat® Enterprise Linux® Microsoft® Windows Server® 2012 Microsoft Windows Server 2008 R2 Enterprise x64 SP1 Microsoft Windows® HPC Server 2008 R2 x64 SP1 |
|||
Server management | Embedded BMC with IPMI
2.0 support with 1x 10/100 Mbps RJ45 connector
Intel Node Manager 2.0 compliant |
|||
Hypervisors | Citrix® XenServer®
VMware® vSphere® ESXi™ Microsoft Hyper-V® Server 2008 R2 SP1 |
|||
Services
(Availability varies by region. Please contact your sales representative for details.) |
Data Center Consulting
Services
Rack Integration (U.S. only, not available in China) Rack Design Verification Configuration Services/CFI Onsite Deployment Online Self Dispatch Basic Support ProSupport for IT |
ProSupport for Data
Center
4-Hour Support Keep Your Hard Drive Enterprise Wide Contract IT Advisory Service Remote Advisory Service Certified Data Destruction Specialized Onsite Services |
|
||||
Bulletin | Latest | Past week | Past month |
|
Adam Hough Adam.Hough at pgs.com
Fri Sep 6 07:50:14 CDT 2013
- Previous message: [Poweredgec-tools] C6220 ipmi fan speed raw command?
- Next message: [Poweredgec-tools] Ipmi command on C6220
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
I am in the process of upgrading the firmware on some of our C6220 systems using the ipmiflash utility. I have several systems that have hung during the "Validating Image" in that it will never exit that stage of the flash. I can kill the update script but leaves the ipmi interface in "update mode". The only way I know how to get it out of this sate it to reseat the sled in the chassis to reboot the ipmi controller as in this state the ipmi controller ignores any reset commands (which is the correct action to prevent bad stuff during the actually flash). Is there a raw ipmi command I can send to get it out of the "update mode"? Adam Hough Senior Computer Systems Engineer, NSA Global Compute ResourcesTwo things about this -
1) for convenience I use ipmiflash on all my test systems. but at scale I use socflash only, because it does raw reads/writes to the flash rom. It never fails. However, socflash defaults the MAC address of the BMC, which you have to put back. So the procedure is to capture those macs, socflash the bmc, put them back. "bmc" tool has a convenience function you can use to facilitate this; you have to run this locally on the box. From memory:bmc get_both_macs | tee /tmp/mymacs
# Be sure to confirm that every /tmp/mymacs file looks right / has macs in it. I've recently seen occasionally that this would fail. (Fix forthcoming)
# Apply a new image; skip image backup step; use the "all*.bin" file when you flash with socflash
socflash_x64 -s allXXXXX.bin
bmc set_both_macs /tmp/mymacs
Note - this wipes all bmc settings including which NIC it uses; so you go back to shared/DHCP.
2) Because of how it works, socflash can also be used to hard reset and/or revive a hung (or even completely dead) BMC. This resets the BMC as a side effect of reading the image and throwing it away. There are very, very few situations where this will not work:
# Hard reset a BMC
socflash of=/dev/null
The user friendly version of that is to get "peclogs" from http://poweredgec.dell.com and run the command line option to reset the bmc (I forget what it's named).Be careful with socflash. It's powerful, but it has quirks and basically no safeties.
Michael Stumpf
Josh_Moore at Dell.com Josh_Moore at Dell.com
System Management & Tools
Dell | PowerEdge C
Fri Sep 6 08:38:29 CDT 2013
- Previous message: [Poweredgec-tools] Ipmi command on C6220
- Next message: [Poweredgec-tools] C6145 setupbios utility
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Dell - Internal Use - Confidential Good morning Adam To add to Michael's information The reset syntax that I have for socflash is socflash option=r of=/dev/null As Michael pointed out, this functionality is built into the pec-logs utility as well, the syntax is pec-logs.sh --bmc-reset Josh Moore
Dell c6220 IPMI controller odditites"The networking configuration of the IPMI controllers on our new Dell c6220 boxes is strange to say the least. We've encountered issues where the IPMI controller binds to a random interface, usually making itself inaccessible to the world.
I've done some digging into this, and it seems that the IPMI controller is really an embedded Linux device (no surprise there). It has two main network interfaces:
- bond0 – This is used for the "shared" network option of the IPMI controller. As far as I can tell this bond is created in active-backup mode. This means that if your primary network interface drops for any reason, the IPMI controller will failover to the secondary network interface. The only way to get it to fail back over to the primary network interface is to briefly down the secondary network interface. Resetting the BMC will have no effect (which is dumb).
- eth1 – This is used for the "dedicated" network option. If you're using this, you should definitely configure the IPMI controller to use it, and don't just rely on it's auto-detection of this.
Speaking of configuring the network mode, you have two options for this '1' or '2'. The documentation doesn't indicate which is which, but based on my testing '1' is shared networking, and '2' is dedicated networking. Seems silly they couldn't manage to put descriptions in for this.
Site: Louisiana State UniversitySystem URL: http://www.hpc.lsu.edu/systems/system.php?system=Supermike2
Manufacturer: Dell
Cores: 7,040
Linpack Performance (Rmax) 110.93 TFlop/s
Theoretical Peak (Rpeak) 146.432 TFlop/s
Power: 200.00 kW
Memory: 14,080 GB Interconnect: Infiniband QDR
Operating System: Linux
Compiler: GCC, gfortran
Math Library: Intel MKL 11.339.sp1
MPI: OpenMPI 1.6
Recommended Links
Top Visited Bulletin Latest Past week Past month Google Search
Dell page
- PowerEdge C6220 II Rack Server Dell
- PowerEdge C6220 II Spec SheetPDF
- Dell PowerEdge C6220: CentOS-based LAMP Performance for Large InfrastructuresPDF
- Dell PowerEdge C6220 and Ubuntu LAMP Reference ArchitecturePDF
- Dell PowerEdge C6220 and FreeBSD AMP Reference ArchitecturePDF
- Dell PowerEdge C6220 and CentOS LAMP Reference ArchitecturePDF
Docs
poweredge-c6220-2_Owner's Manual_en-us.pdf poweredge-c6220_Deployment Guide9_en-us.pdf poweredge-c6220_Owner's Manual2_en-us.pdf YouTube
Deployment examples
- Chengdu University of Information Technology (CUIT) collaborates with Dell to devise energy efficient VDIPDF
- Huevocartoon Producciones deploys powerful render farm for 3-D animation productionPDF
- National Institute of Informatics (NII)PDF
- Ecole Polytechnique Fédérale de Lausanne (EPFL) boosts research with HPCPDF
- University of Cambridge (UoC)PDF
- LexisNexisPDF
- EMD InternationalPDF
- Jacobs University BremenPDF
- ACK STORMPDF
- CERNPDF
- Reel FXPDF
- Blue ZooPDF
Etc
- net.DE ensures its customers uptime with energy efficient cloud serversPDF
- PowerEdge Portfolio BrochurePDF
- PowerEdge C6220 Spec SheetPDF
- Dell PowerEdge C6220: Powerful, streamlined, and efficientPDF
- Dell PowerEdge C6220 Technical Guide PDF
- PowerEdge C6220 II Technical Guide PDF
- PowerEdge C6220 Spec SheetPDF
- PowerEdge C6220 II Spec SheetPDF
- PowerEdge C6220 II Spec SheetPDF
Etc
Society
Groupthink : Two Party System as Polyarchy : Corruption of Regulators : Bureaucracies : Understanding Micromanagers and Control Freaks : Toxic Managers : Harvard Mafia : Diplomatic Communication : Surviving a Bad Performance Review : Insufficient Retirement Funds as Immanent Problem of Neoliberal Regime : PseudoScience : Who Rules America : Neoliberalism : The Iron Law of Oligarchy : Libertarian Philosophy
Quotes
War and Peace : Skeptical Finance : John Kenneth Galbraith :Talleyrand : Oscar Wilde : Otto Von Bismarck : Keynes : George Carlin : Skeptics : Propaganda : SE quotes : Language Design and Programming Quotes : Random IT-related quotes : Somerset Maugham : Marcus Aurelius : Kurt Vonnegut : Eric Hoffer : Winston Churchill : Napoleon Bonaparte : Ambrose Bierce : Bernard Shaw : Mark Twain Quotes
Bulletin:
Vol 25, No.12 (December, 2013) Rational Fools vs. Efficient Crooks The efficient markets hypothesis : Political Skeptic Bulletin, 2013 : Unemployment Bulletin, 2010 : Vol 23, No.10 (October, 2011) An observation about corporate security departments : Slightly Skeptical Euromaydan Chronicles, June 2014 : Greenspan legacy bulletin, 2008 : Vol 25, No.10 (October, 2013) Cryptolocker Trojan (Win32/Crilock.A) : Vol 25, No.08 (August, 2013) Cloud providers as intelligence collection hubs : Financial Humor Bulletin, 2010 : Inequality Bulletin, 2009 : Financial Humor Bulletin, 2008 : Copyleft Problems Bulletin, 2004 : Financial Humor Bulletin, 2011 : Energy Bulletin, 2010 : Malware Protection Bulletin, 2010 : Vol 26, No.1 (January, 2013) Object-Oriented Cult : Political Skeptic Bulletin, 2011 : Vol 23, No.11 (November, 2011) Softpanorama classification of sysadmin horror stories : Vol 25, No.05 (May, 2013) Corporate bullshit as a communication method : Vol 25, No.06 (June, 2013) A Note on the Relationship of Brooks Law and Conway Law
History:
Fifty glorious years (1950-2000): the triumph of the US computer engineering : Donald Knuth : TAoCP and its Influence of Computer Science : Richard Stallman : Linus Torvalds : Larry Wall : John K. Ousterhout : CTSS : Multix OS Unix History : Unix shell history : VI editor : History of pipes concept : Solaris : MS DOS : Programming Languages History : PL/1 : Simula 67 : C : History of GCC development : Scripting Languages : Perl history : OS History : Mail : DNS : SSH : CPU Instruction Sets : SPARC systems 1987-2006 : Norton Commander : Norton Utilities : Norton Ghost : Frontpage history : Malware Defense History : GNU Screen : OSS early history
Classic books:
The Peter Principle : Parkinson Law : 1984 : The Mythical Man-Month : How to Solve It by George Polya : The Art of Computer Programming : The Elements of Programming Style : The Unix Hater’s Handbook : The Jargon file : The True Believer : Programming Pearls : The Good Soldier Svejk : The Power Elite
Most popular humor pages:
Manifest of the Softpanorama IT Slacker Society : Ten Commandments of the IT Slackers Society : Computer Humor Collection : BSD Logo Story : The Cuckoo's Egg : IT Slang : C++ Humor : ARE YOU A BBS ADDICT? : The Perl Purity Test : Object oriented programmers of all nations : Financial Humor : Financial Humor Bulletin, 2008 : Financial Humor Bulletin, 2010 : The Most Comprehensive Collection of Editor-related Humor : Programming Language Humor : Goldman Sachs related humor : Greenspan humor : C Humor : Scripting Humor : Real Programmers Humor : Web Humor : GPL-related Humor : OFM Humor : Politically Incorrect Humor : IDS Humor : "Linux Sucks" Humor : Russian Musical Humor : Best Russian Programmer Humor : Microsoft plans to buy Catholic Church : Richard Stallman Related Humor : Admin Humor : Perl-related Humor : Linus Torvalds Related humor : PseudoScience Related Humor : Networking Humor : Shell Humor : Financial Humor Bulletin, 2011 : Financial Humor Bulletin, 2012 : Financial Humor Bulletin, 2013 : Java Humor : Software Engineering Humor : Sun Solaris Related Humor : Education Humor : IBM Humor : Assembler-related Humor : VIM Humor : Computer Viruses Humor : Bright tomorrow is rescheduled to a day after tomorrow : Classic Computer Humor
The Last but not Least Technology is dominated by two types of people: those who understand what they do not manage and those who manage what they do not understand ~Archibald Putt. Ph.D
Copyright © 1996-2021 by Softpanorama Society. www.softpanorama.org was initially created as a service to the (now defunct) UN Sustainable Development Networking Programme (SDNP) without any remuneration. This document is an industrial compilation designed and created exclusively for educational use and is distributed under the Softpanorama Content License. Original materials copyright belong to respective owners. Quotes are made for educational purposes only in compliance with the fair use doctrine.
FAIR USE NOTICE This site contains copyrighted material the use of which has not always been specifically authorized by the copyright owner. We are making such material available to advance understanding of computer science, IT technology, economic, scientific, and social issues. We believe this constitutes a 'fair use' of any such copyrighted material as provided by section 107 of the US Copyright Law according to which such material can be distributed without profit exclusively for research and educational purposes.
This is a Spartan WHYFF (We Help You For Free) site written by people for whom English is not a native language. Grammar and spelling errors should be expected. The site contain some broken links as it develops like a living tree...
You can use PayPal to to buy a cup of coffee for authors of this site Disclaimer:
The statements, views and opinions presented on this web page are those of the author (or referenced source) and are not endorsed by, nor do they necessarily reflect, the opinions of the Softpanorama society. We do not warrant the correctness of the information provided or its fitness for any purpose. The site uses AdSense so you need to be aware of Google privacy policy. You you do not want to be tracked by Google please disable Javascript for this site. This site is perfectly usable without Javascript.
Last modified: March 12, 2019