Intel® Xeon® E5640 (4 core, 2.66 GHz, 12MB L3, 80W) Intel® Xeon® Number of processors 2
Memory 12 GB
Smart Array P410i/1GB (1)
Power Supply (2) 460 Watt 92% Efficiency, hot plug, redundant
Hard Drives 4 x 146G 15K RPM hot swappable.
|
Switchboard | ||||
Latest | |||||
Past week | |||||
Past month |
DL360 G7 not showing new drives in slots 5 & 6 - HP Enterprise Business Community
Jennifer NordengOccasional Contributor
Posts: 9
Registered: 03-17-2010Message 1 of 5 (7,175 Views)
Post options
07-06-2012 03:20 PM
I just added 2 new drives to my 2 DL360G7 servers which are the same build and config. I am not seeing the system recognize them at all with the SmartStart ACU or even physically, no lights or anything are apparent when the drives are insterted into the system. They are the same configuration, including same part number and all are 15k. I feel that I might have missed something, but dont' think I need another controller to use these slots, would someone please give me an idea if there is something else I am missing?
The system is currently configuration o 2x146GB sets of Raid 1+-0. I just expanded the original array from 2 to 4 drives, but the 2 new drives which would make this 6 in the system aren't visible at all.
Thanks in advance for your help.
View All (1)
Reply
Suman_1978
HP Pro
Posts: 1,276
Registered: 12-07-2010Re: DL360 G7 not showing new drives in slots 5 & 6
Post options07-08-2012 07:20 PM
Hi,
Take a look at the below links:
DL360 G7 Storage Configuration.
I am not sure if you have 8 HDD backplane or 6 HDD backplane with DVD Drive.
Bay 5, 6 not available when DVD installed.
4 SFF Bays standard with option for up to 8 SFF drive bays total.
NOTE: 4 bays standard in Entry, Base and CTO models, with optional upgrade to 8 bays with the SFF HD Backplane Kit (516966-B21). No CD or DVD options available when server is configured with 8 drive bays.
Thanks
Jennifer NordengOccasional Contributor
Posts: 9
Registered: 03-17-2010Message 3 of 5 (7,146 Views)
Re: DL360 G7 not showing new drives in slots 5 & 6
Post options07-09-2012 08:16 AM
I had in production originally 4 146GB SAS drives and DVD drive which is in slot 7 and 8, but 5 and 6 just had an insert.
So, you are saying because of having the DVD drive, slots 5 and 6 are only capable of an insert? Or, do I need another component to use this space? Thanks.
Reply
0
0
Suman_1978
HP Pro
Posts: 1,276
Registered: 12-07-2010Message 4 of 5 (7,132 Views)
Re: DL360 G7 not showing new drives in slots 5 & 6
Post options07-09-2012 07:18 PM
Hi,
The documentation says that if Optical drive is installed then only drives bay 1-4 works, 5-6 do not work.
You may also refer to this link:
HP ProLiant DL360 G7 Server User Guide
http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c02065265/c02065265.pdfPage# 48 = This server supports the installation of a DVD-ROM drive or a DVD-RW drive. When an optical drive is installed, the server does not support the additional hard drive backplane.
Page# 51 = When the hard drive backplane option is installed, the server does not support the DVD-ROM or DVD-RW drive options.
Page# 68 and 69 = Hard drive backplane cabling
Thank You!
__________________________________________
Was the post useful? Click on the white KUDOS! Star.For product specific Guided Troubleshooting visit; http://www.hp.com/support/hpgt
Want to know How to use HP Guided Troubleshooting? Visit the below link.
http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c03283214
Reply
0
0
kkapadia
Occasional Visitor
Posts: 1
Registered: 06-06-2013Message 5 of 5 (6,720 Views)
Re: DL360 G7 not showing new drives in slots 5 & 6
Post options06-06-2013 07:29 AM
I have the same issue. It does not recognize drive 5 & 6. Can I disable the CD drive I have and make it recognize drive 5 and 6?
Jennifer Nordeng wrote:
I just added 2 new drives to my 2 DL360G7 servers which are the same build and config. I am not seeing the system recognize them at all with the SmartStart ACU or even physically, no lights or anything are apparent when the drives are insterted into the system. They are the same configuration, including same part number and all are 15k. I feel that I might have missed something, but dont' think I need another controller to use these slots, would someone please give me an idea if there is something else I am missing?
The system is currently configuration o 2x146GB sets of Raid 1+-0. I just expanded the original array from 2 to 4 drives, but the 2 new drives which would make this 6 in the system aren't visible at all.
Thanks in advance for your help.
Reply
0
0
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation.
End content
Open Country/Region Selector Dialog United States
Google matched content |
HP CTO ONLY ILO ADV E-LTU INC 1YR - TA850AAE - Storage Networking-SAN Software - CDW.comIf possible, please base your order on the manufacturer part number ( TA850AAE ). If you are unsure about exactly what you need, please consult the manufacturer's web site or call us at
Product Description800-336-1166. HP ProLiant Essentials Integrated Lights-Out Advanced Pack - license
Bundled Support: 1 Year 24x7 Support License Qty 1 server License Pricing
Detailed Description: Integrated Lights-Out (iLO) Advanced Pack gives you the ultimate remote control of system resources located in data centers and remote sites. With an iLO Advanced license key, you can activate powerful remote management features to install, configure, monitor, update, and troubleshoot remote ProLiant servers anywhere, anytime from a standard Web browser, command line or script. Product Description: HP ProLiant Essentials Integrated Lights-Out Advanced Pack, Electronic, including 1 year of 24x7 Technical Support and Updates Software Bundled Support: 1 Year 24x7 Support Category: Networking applications
▶ Velocity Tech Solutions - HP ProLiant DL360 G7 Server Overview - YouTube
▶ HP ProLiant DL360 G7 - YouTube