Hardware vendors now incorporate hardware for remote management of boxes. IPMI 2.0 has become the current standard. IPMI offers a way to remotely power-cycle a machine, as well as to have remote console viewable to see the machine boot from BIOS. IPMI is quite powerful -- we could change BIOS settings, reboot the nodes, and watch them boot up and see the screen dump without ever seeing the machine . Terminal servers such as the Cyclades ACS48 remain a reasonable investment and provide out-of-band access and reliability that IPMI does not quite deliver.
DRAC is essentially a web interface to IPMI via a separate small bootable computer on a standard card. For most Dell PowerEdge models, the DRAC exists as an option that you can add to your server configuration. This option adds approximately $300 at the list price to your server configuration, but if you server is installed in remote location it is more then worth the cost. The DRAC on current models is a separate chipset and board that is connected to the server main board but has its own network interface. It can be configured during the boot process as direct configuration is accessible during system initialization.
From the DRAC you can manage media, power, integrated system log messages, and have a remote view of the console. The DRAC is similar to the Hewlett Packard Integrated Lights-Out (iLO) but it is more reliable (see ILO 3 -- HP engineering fiasco)
DRAC card can use either DHCP or static address.
Access to DRAC user accounts is protected by passwords. Default account and password is provided by Dell. You should change it to avoid a trivial backdoor to the server. When the DRAC initializes, you can enter into a configuration screen to get the basic IP address and credentials set. Once this is set, you can further access the system through the web-based interface. Pressing Ctrl-D will take you into the DRAC board setup where you can make basic settings changes. Once you configure the IP address is configured, you can configure additional users and the timeout values for the network sessions.
Note: The default session timeout value is five minutes, you need to increase it to more reasonable value, say 1920 seconds. You can also do it from Remote Access /Configuration/Services menu via HTTP.
There are slight differences in the DRAC’s web interface across models.
Probably the strongest feature of the DRAC is the media redirection capability. From the web interface, you can redirect the server's CD-ROM and floppy media to that of your web client or an image file. The best application for this is for a brand new server and no operating system is installed. With DRAC media redirection, a CD-ROM .ISO image of an operating system can be configured to be the CD-ROM and the installation can proceed from the virtual CD-ROM without physical media being inserted into the server.
This is workable, tested solution for server installation in remote datacenters without boots on the ground.
The one caveat to watch for is the boot order in the BIOS. Frequently, the default configuration will have the DRAC's redirected CD-ROM as a bootable device - but, if it's below the physical CD-ROM it may not boot correctly. In the BIOS, it is listed as "Virtual CD-ROM" and the equivalent for the floppy drive.
The DRAC provides the ability to remotely power off, power on, reset, and power cycle the system, regardless of the state of the operating system. This is especially handy in situations such as the blue screen of death or otherwise failed system that no native interaction can resolve. Be especially careful with the use of the remote power controls since this is one feature that always does as it is told. The security models in place can allow you to prohibit the power controls, called "server control commands." You should consider in larger environments.
The DRAC console also provides a redirection of the video display, also regardless of the operating system state. So, you could connect and see the blue screen of death, jump into the server's BIOS to configure the boot order, install an operating system, or view the console of the operating system as it's running. There are two sessions to the console permitted in most configurations. Note that these two sessions may be in addition to an operating system method, a physical console session, and any additional hardware - such as a keyboard, video, mouse controller or software such as PC Anywhere.
One downside of the DRAC is that on certain models if the DRAC is selected, the onboard video (both rear and front side) interfaces are rendered inoperable by the presence of the DRAC video interface. Dell usually has markers indicating that these interfaces are not available. However, these may get removed and, should you have a monitor connected to the incorrect interface, there would be no video displayed.
The DRAC has a firmware that's separate from the computer's firmware. From support.dell.com, you can download the appropriate firmware for the DRAC model in your system. The DRAC can also provide you the service tag, making the retrieval easier. I recommend that you keep this firmware up to date as inevitably some piece of functionality may not work correctly on the firmware you currently have on the unit. This is where, in my experience, the iLO has been a better remote management device. The DRAC firmware should be updated, whereas you didn't used to have to worry about the iLO firmware.
Be sure to note that within the DRAC you have access to the integrated system logs. This would include notes such as power supply failed, chassis opened, or a memory module failure. The DRAC 5 can even provide running temperatures on the system board. This can be especially beneficial in remote, harsh environment situations where unexpected results are occurring and thermal data would identify an issue. The DRAC also allows for Active Directory integration, certificate management, SNMP traps, and basic email alerting for the status of the device.
Logging In
You can log in either as a DRAC 5 user or as a Microsoft® Active Directory® user. The default user name and password are root and calvin, respectively.
Before you log in to the DRAC 5, verify that you have Log In to DRAC 5 permission. Speak to your organization's DRAC or network administrator to confirm your access privileges.
To log in:
- In the User Name field, type one of the following:
- Your DRAC 5 user name.
For example, <username>
The DRAC 5 user name for local users is case sensitive
- Your Active Directory user name.
For example, <domain>\<username>, <domain>/<username>, or <user>@<domain>.
Examples of an Active Directory user name are: dell.com\john_doe or [email protected].
The Active Directory user name is not case sensitive.
- In the Password field, type your DRAC 5 user password or Active Directory user password.
This field is case sensitive.
- Click OK or press <Enter>.
Logging Out
- In the upper-right corner of the DRAC 5 Web-based interface window, click Log Out to close the session.
- Close the browser window.
NOTE: The Log Out button does not appear until you log in.
NOTE: Closing the browser without gracefully logging out causes the session to remain open until it times out. It is strongly recommended that you click the logout button to end the session; otherwise, the session remains active until the session timeout is reached.
NOTE: Closing the DRAC 5 Web-based interface within Microsoft Internet Explorer using the close button ("x") at the top right corner of the window may generate an application error. To fix this issue, download the latest Cumulative Security Update for Internet Explorer from the Microsoft Support website, at support.microsoft.com.
Enabling and Configuring the Managed System to Use a Serial or Telnet Console
The following subsections provide information about how to enable and configure a serial/telnet/ssh console on the managed system.
Using the connect com2 Serial Command
When using the connect com2 serial command, ensure that the following are configured properly:
- The Serial Communication→ Serial Port setting in the BIOS Setup program.
- The DRAC configuration settings.
When a telnet session is established to the DRAC 5 and these settings are incorrect, connect com2 may display a blank screen.
Configuring the BIOS Setup Program for a Serial Connection on the Managed System
Perform the following steps to configure your BIOS Setup program to redirect output to a serial port.
NOTE: You must configure the System Setup program in conjunction with the connect com2 command.
- Turn on or restart your system.
- Press <F2> immediately after you see the following message:
<F2> = System Setup
- Scroll down and select Serial Communication by pressing <Enter>.
- Set the Serial Communication screen as follows:
External Serial Connector - Remote Access Device
Redirection After Boot - Disabled
- Press <Esc> to exit the System Setup program to complete the System Setup program configuration.
Using the Remote Access Serial Interface
When establishing a serial connection to the RAC device, the following interfaces are available:
- IPMI serial interface. See "Using the IPMI Remote Access Serial Interface."
- RAC serial interface
RAC Serial Interface
RAC also supports a serial console interface (or RAC Serial Console) that provides a RAC CLI, which is not defined by IPMI. If your system includes a RAC card with Serial Console enabled, the RAC card will override the IPMI serial settings and display the RAC CLI serial interface.
To enable the RAC serial terminal interface, set the cfgSerialConsoleEnable property to 1 (TRUE).
For example:
racadm config -g cfgSerial -o cfgSerialConsoleEnable 1
See "cfgSerialConsoleEnable (Read/Write)" for more information.
Table 4-1 provides the serial interface settings.
Table 4-1. Serial Interface Settings
IPMI Mode RAC Serial Console Interface Basic Disabled Basic Mode Basic Enabled RAC CLI Terminal Disabled IPMI Terminal Mode Terminal Enabled RAC CLI
Configuring Linux for Serial Console Redirection During Boot
The following steps are specific to the Linux GRand Unified Bootloader (GRUB). Similar changes would be necessary if you use a different boot loader.
NOTE: When you configure the client VT100 emulation window, set the window or application that is displaying the redirected console to 25 rows x 80 columns to ensure proper text display; otherwise, some text screens may be garbled. Edit the /etc/grub.conf file as follows:
- Locate the General Setting sections in the file and add the following two new lines:
serial --unit=1 --speed=57600
terminal --timeout=10 serial
- Append two options to the kernel line:
kernel ............. console=ttyS1,57600
- If the /etc/grub.conf contains a splashimage directive, comment it out.
Table 4-2 provides a sample /etc/grub.conf file that shows the changes described in this procedure.
Table 4-2. Sample File: /etc/grub.conf
# grub.conf generated by anaconda
#
# Note that you do not have to rerun grub after making changes
# to this file
# NOTICE: You do not have a /boot partition. This means that
# all kernel and initrd paths are relative to /, e.g.
# root (hd0,0)
# kernel /boot/vmlinuz-version ro root= /dev/sdal
# initrd /boot/initrd-version.img
#
#boot=/dev/sda
default=0
timeout=10
#splashimage=(hd0,2)/grub/splash.xpm.gzserial --unit=1 --speed=57600
terminal --timeout=10 serial
title Red Hat Linux Advanced Server (2.4.9-e.3smp)
root (hd0,0)
kernel /boot/vmlinuz-2.4.9-e.3smp ro root= /dev/sda1 hda=ide-scsi console=ttyS0 console= ttyS1,57600
initrd /boot/initrd-2.4.9-e.3smp.img
title Red Hat Linux Advanced Server-up (2.4.9-e.3)
root (hd0,00)
kernel /boot/vmlinuz-2.4.9-e.3 ro root=/dev/sda1 s
initrd /boot/initrd-2.4.9-e.3.im
When you edit the /etc/grub.conf file, use the following guidelines:
- Disable GRUB's graphical interface and use the text-based interface; otherwise, the GRUB screen will not be displayed in RAC console redirection. To disable the graphical interface, comment out the line starting with splashimage.
- To enable multiple GRUB options to start console sessions through the RAC serial connection, add the following line to all options:
console=ttyS1,57600
Table 4-2 shows console=ttyS1,57600 added to only the first option.
Enabling Login to the Console After Boot
Edit the file /etc/inittab as follows:
Add a new line to configure agetty on the COM2 serial port:
co:2345:respawn:/sbin/agetty -h -L 57600 ttyS1 ansi
Table 4-3 shows a sample file with the new line.
Table 4-3. Sample File: /etc/innitab
#
# inittab This file describes how the INIT process should set up
# the system in a certain run-level.
#
# Author: Miquel van Smoorenburg
# Modified for RHS Linux by Marc Ewing and Donnie Barnes
#
# Default runlevel. The runlevels used by RHS are:
# 0 - halt (Do NOT set initdefault to this)
# 1 - Single user mode
# 2 - Multiuser, without NFS (The same as 3, if you do not have
# networking)
# 3 - Full multiuser mode
# 4 - unused
# 5 - X11
# 6 - reboot (Do NOT set initdefault to this)
#
id:3:initdefault:# System initialization.
si::sysinit:/etc/rc.d/rc.sysinit
l0:0:wait:/etc/rc.d/rc 0
l1:1:wait:/etc/rc.d/rc 1
l2:2:wait:/etc/rc.d/rc 2
l3:3:wait:/etc/rc.d/rc 3
l4:4:wait:/etc/rc.d/rc 4
l5:5:wait:/etc/rc.d/rc 5
l6:6:wait:/etc/rc.d/rc 6# Things to run in every runlevel.
ud::once:/sbin/update# Trap CTRL-ALT-DELETE
ca::ctrlaltdel:/sbin/shutdown -t3 -r now# When our UPS tells us power has failed, assume we have a few
# minutes of power left. Schedule a shutdown for 2 minutes from now.
# This does, of course, assume you have power installed and your
# UPS is connected and working correctly.
pf::powerfail:/sbin/shutdown -f -h +2 "Power Failure; System Shutting Down"
# If power was restored before the shutdown kicked in, cancel it.
pr:12345:powerokwait:/sbin/shutdown -c "Power Restored; Shutdown Cancelled"
# Run gettys in standard runlevels
co:2345:respawn:/sbin/agetty -h -L 57600 ttyS1 ansi
1:2345:respawn:/sbin/mingetty tty1
2:2345:respawn:/sbin/mingetty tty2
3:2345:respawn:/sbin/mingetty tty3
4:2345:respawn:/sbin/mingetty tty4
5:2345:respawn:/sbin/mingetty tty5
6:2345:respawn:/sbin/mingetty tty6# Run xdm in runlevel 5
# xdm is now a separate service
x:5:respawn:/etc/X11/prefdm -nodaemon
Edit the file /etc/securetty as follows:
Add a new line with the name of the serial tty for COM2:
ttyS1
Table 4-4 shows a sample file with the new line.
Table 4-4. Sample File: /etc/securetty
vc/1
vc/2
vc/3
vc/4
vc/5
vc/6
vc/7
vc/8
vc/9
vc/10
vc/11
tty1
tty2
tty3
tty4
tty5
tty6
tty7
tty8
tty9
tty10
tty11
ttyS1
Enabling the DRAC 5 Serial/Telnet/SSH Console
The serial/telnet/ssh console can be enabled locally or remotely.
Enabling the Serial/Telnet/SSH Console Locally
NOTE: You (the current user) must have Configure DRAC 5 permission in order to perform the steps in this section. To enable the serial/telnet/ssh console from the managed system, type the following local RACADM commands from a command prompt:
racadm config -g cfgSerial -o cfgSerialConsoleEnable 1
racadm config -g cfgSerial -o cfgSerialTelnetEnable 1
racadm config -g cfgSerial -o cfgSerialSshEnable 1
Enabling the Serial/Telnet/SSH Console Remotely
To enable the serial/telnet/ssh console remotely, type the following remote RACADM commands from a command prompt:
racadm -u <username> -p <password> -r <DRAC 5 IP address> config -g cfgSerial -o cfgSerialConsoleEnable 1
racadm -u <username> -p <password> -r <DRAC 5 IP address> config -g cfgSerial -o cfgSerialTelnetEnable 1
racadm -u <username> -p <password> -r <DRAC 5 IP address> config -g cfgSerial -o cfgSerialSshEnable 1
NOTE: When you use Internet Explorer version 6 SP2 or version 7 to log into a managed system on a private network, but without access to the Internet, you may experience a delay of up to 30 seconds while using remote RACADM commands. Using the RACADM Command to Configure the Settings
Oct 10, 2007 losalamos.redhawk.orgThe setup for ssh concole access on the DELL DRAC.
This setup shows using DHCP for the DRAC ip address, but it can be hard set as well.
* Enter setup F2 1. Cursor down to Serial Communications. 2. Set the other fields to the following. o Serial Communication : On with console Redirection via COM2 o External Serial Connector : Remote Access Device o Failsafe Baud Rate : 57600 o Remote Terminal Type : VT100/VT200 o Redirection After Boot: Enabled 3. Save and exit. * Enter the RAC configuration when prompted CTRL-E o Set the ip address to DHCP o Set the LAN User password to the current console password. o Write down the DRAC MAC address. o Save and ExitEnter the MAC address in dhcp on your dhcp server dhcpd.conf in the appropriate section.
Restart DHCPNow we should be able to ssh to the console.
ssh vt-11-c -l root root@vt-11-c's password: Warning: No xauth data; using fake authentication data for X11 forwarding. Dell Remote Access Controller 5 (DRAC 5) Firmware Version 1.20 (Build 07.03.02) $To get to the console type:connect com2This message flashes...Connected to com2. To end type: '^\'Then you should have the console login.Red Hat Enterprise Linux WS release 4 (Nahant Update 5) Kernel 2.6.9-55.ELsmp on an x86_64 vt-11 login:To escape type 'CTRL' + '\'$To change root password on a DRAC from ssh shell$ racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 2 NewPasswordHereNow to do power tasks on the dell type smclp.$ smclp DRAC5 SM-CLP System Management Shell, version 1.0 Copyright (c) 2004-2007 Dell, Inc. All Rights Reserved cd system1 /system1 show /system1: Targets: logs1 Properties: CreationClassName = CIM_ComputerSystem Name = 7B0CZC1 NameFormat = other Dedicated = 0 ResetCapability = 4 EnabledState = 2 RequestedState = 12 EnabledDefault = 2 HealthState = 5 OperationalStatus = 2 Description = PowerEdge 2970 Verbs: cd exit help reset show start stop version * To reboot the system type "reset" * To power off "stop" * To power on "start"
October 30, 2008
John:
I was just at our colo replacing a dead fan on one of our servers and the data-center guy was talking about how they call DRAC "drag" because it's so slow. I mean… not that funny I guess…
Alex:
We have DRAC 5 cards in about 100 Dell 2950 systems and IMHO they work great.
Very fast and useful even for remote server installs, by mounting the media.
DRAC 4 cards Dell 2850 are useful as well but with a lot of bugs, some of them work like a charm, some cannot be accessed despite all the software reinstalls and firmware upgrades
DRAC 3 cards: USELESS and slow to extreme. GUI next to imposible to use, telnet is OK
DRAC/MC in 1855 blades, very slow as well, Https will time out half times.
Just our experience,
Alex
Dell Remote Access Controller 5 Firmware Version 1.30 User's Guide
First Steps to Troubleshoot a Remote System
Managing Power on a Remote System
Using the System Event Log (SEL)
Viewing the Last System Crash Screen
Troubleshooting Network Problems
Troubleshooting Alerting Problems
Why do I receive an "Out of Scan Range," "Synch out of Range," or "No Sync Input" message when I power my system off?
When the system is powered off, it stops sending a signal to the monitor. These messages indicate that the monitor is no longer receiving a signal from the computer.Out of Scan Range, Synch out of Range, or No Sync Input Message When the System is Powered Off.
When you shut down your system, one of the following messages may appear on the monitor screen:
Out of Scan Range
Synch Out of Range
No Sync InputThese messages may flash by quickly or may stay until the monitor is powered off.
Dell Extends Technology Leadership With Next-Generation Powe - ITReseller.com
Contents Dell Remote Access Controller 5 (DRAC 5) Version 1.20
Readme | View | Download | (TXT, 11 KB) |
User's Guide | View | Download | (HTML, 917 KB) |
User's Guide | View | Download | (PDF, 1.03 MB) |
DellRemoteAccessController5Security
What you need to know about the Dell DRAC | TechRepublic
Configuring and Using the DRAC 5 Command Line Console
Society
Groupthink : Two Party System as Polyarchy : Corruption of Regulators : Bureaucracies : Understanding Micromanagers and Control Freaks : Toxic Managers : Harvard Mafia : Diplomatic Communication : Surviving a Bad Performance Review : Insufficient Retirement Funds as Immanent Problem of Neoliberal Regime : PseudoScience : Who Rules America : Neoliberalism : The Iron Law of Oligarchy : Libertarian Philosophy
Quotes
War and Peace : Skeptical Finance : John Kenneth Galbraith :Talleyrand : Oscar Wilde : Otto Von Bismarck : Keynes : George Carlin : Skeptics : Propaganda : SE quotes : Language Design and Programming Quotes : Random IT-related quotes : Somerset Maugham : Marcus Aurelius : Kurt Vonnegut : Eric Hoffer : Winston Churchill : Napoleon Bonaparte : Ambrose Bierce : Bernard Shaw : Mark Twain Quotes
Bulletin:
Vol 25, No.12 (December, 2013) Rational Fools vs. Efficient Crooks The efficient markets hypothesis : Political Skeptic Bulletin, 2013 : Unemployment Bulletin, 2010 : Vol 23, No.10 (October, 2011) An observation about corporate security departments : Slightly Skeptical Euromaydan Chronicles, June 2014 : Greenspan legacy bulletin, 2008 : Vol 25, No.10 (October, 2013) Cryptolocker Trojan (Win32/Crilock.A) : Vol 25, No.08 (August, 2013) Cloud providers as intelligence collection hubs : Financial Humor Bulletin, 2010 : Inequality Bulletin, 2009 : Financial Humor Bulletin, 2008 : Copyleft Problems Bulletin, 2004 : Financial Humor Bulletin, 2011 : Energy Bulletin, 2010 : Malware Protection Bulletin, 2010 : Vol 26, No.1 (January, 2013) Object-Oriented Cult : Political Skeptic Bulletin, 2011 : Vol 23, No.11 (November, 2011) Softpanorama classification of sysadmin horror stories : Vol 25, No.05 (May, 2013) Corporate bullshit as a communication method : Vol 25, No.06 (June, 2013) A Note on the Relationship of Brooks Law and Conway Law
History:
Fifty glorious years (1950-2000): the triumph of the US computer engineering : Donald Knuth : TAoCP and its Influence of Computer Science : Richard Stallman : Linus Torvalds : Larry Wall : John K. Ousterhout : CTSS : Multix OS Unix History : Unix shell history : VI editor : History of pipes concept : Solaris : MS DOS : Programming Languages History : PL/1 : Simula 67 : C : History of GCC development : Scripting Languages : Perl history : OS History : Mail : DNS : SSH : CPU Instruction Sets : SPARC systems 1987-2006 : Norton Commander : Norton Utilities : Norton Ghost : Frontpage history : Malware Defense History : GNU Screen : OSS early history
Classic books:
The Peter Principle : Parkinson Law : 1984 : The Mythical Man-Month : How to Solve It by George Polya : The Art of Computer Programming : The Elements of Programming Style : The Unix Hater’s Handbook : The Jargon file : The True Believer : Programming Pearls : The Good Soldier Svejk : The Power Elite
Most popular humor pages:
Manifest of the Softpanorama IT Slacker Society : Ten Commandments of the IT Slackers Society : Computer Humor Collection : BSD Logo Story : The Cuckoo's Egg : IT Slang : C++ Humor : ARE YOU A BBS ADDICT? : The Perl Purity Test : Object oriented programmers of all nations : Financial Humor : Financial Humor Bulletin, 2008 : Financial Humor Bulletin, 2010 : The Most Comprehensive Collection of Editor-related Humor : Programming Language Humor : Goldman Sachs related humor : Greenspan humor : C Humor : Scripting Humor : Real Programmers Humor : Web Humor : GPL-related Humor : OFM Humor : Politically Incorrect Humor : IDS Humor : "Linux Sucks" Humor : Russian Musical Humor : Best Russian Programmer Humor : Microsoft plans to buy Catholic Church : Richard Stallman Related Humor : Admin Humor : Perl-related Humor : Linus Torvalds Related humor : PseudoScience Related Humor : Networking Humor : Shell Humor : Financial Humor Bulletin, 2011 : Financial Humor Bulletin, 2012 : Financial Humor Bulletin, 2013 : Java Humor : Software Engineering Humor : Sun Solaris Related Humor : Education Humor : IBM Humor : Assembler-related Humor : VIM Humor : Computer Viruses Humor : Bright tomorrow is rescheduled to a day after tomorrow : Classic Computer Humor
The Last but not Least Technology is dominated by two types of people: those who understand what they do not manage and those who manage what they do not understand ~Archibald Putt. Ph.D
Copyright © 1996-2021 by Softpanorama Society. www.softpanorama.org was initially created as a service to the (now defunct) UN Sustainable Development Networking Programme (SDNP) without any remuneration. This document is an industrial compilation designed and created exclusively for educational use and is distributed under the Softpanorama Content License. Original materials copyright belong to respective owners. Quotes are made for educational purposes only in compliance with the fair use doctrine.
FAIR USE NOTICE This site contains copyrighted material the use of which has not always been specifically authorized by the copyright owner. We are making such material available to advance understanding of computer science, IT technology, economic, scientific, and social issues. We believe this constitutes a 'fair use' of any such copyrighted material as provided by section 107 of the US Copyright Law according to which such material can be distributed without profit exclusively for research and educational purposes.
This is a Spartan WHYFF (We Help You For Free) site written by people for whom English is not a native language. Grammar and spelling errors should be expected. The site contain some broken links as it develops like a living tree...
|
You can use PayPal to to buy a cup of coffee for authors of this site |
Disclaimer:
The statements, views and opinions presented on this web page are those of the author (or referenced source) and are not endorsed by, nor do they necessarily reflect, the opinions of the Softpanorama society. We do not warrant the correctness of the information provided or its fitness for any purpose. The site uses AdSense so you need to be aware of Google privacy policy. You you do not want to be tracked by Google please disable Javascript for this site. This site is perfectly usable without Javascript.
Last modified: March, 12, 2019